ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
d.
(1) Place engine RUN lever to RUN position.
(2) Pull slack from LOP engine shutdown cable in direction of arrow A.
(3) Measure for dimension B [0-0.02 in. (0-0.5 mm)].
(4) Pull cable from LOP solenoid and grommet. Remove LOP solenoid plunger, cut
cable as necessary to achieve dimension B. Attach LOP solenoid plunger to LOP
engine shutdown cable and install cable in LOP solenoid and grommet.
(5) Return engine RUN lever to STOP position.
AIR INTAKE HEATING ELEMENTS AND PIPE.
a.
Removal.
(STOP)
(RUN)
BLACK RUN LEVER
RED STOP LEVER
GOVERNOR
REGULATOR
BRACKET
A
LOP ENGINE SHUTDOWN CABLE
B