ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
NOTES:
1. Dimensions shown are in inches.
2. Refer to TM 9-6115-641-24P for materials
required.
PROCEDURES:
1. Cut rope (1) to length indicated.
2. Slide insulation sleeving (2) over one end of
rope (1).
3. Crimp terminal (3) on each end of rope (1).
4. Install hook (4) in one terminal (3) and close
hook end securing it to terminal.
5. Position insulation sleeving (2) as shown and
shrink to fit.
Figure D-8. Holder, Control Panel (P/N: 88-20134)
D - 8