ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
NOTES:
PROCEDURES:
1. Refer to TM 9-6115-641-24P for materials
1. Strip 0.125 inch of insulation from end of each
required.
solenoid (1) lead.
2. Crimp pins (2) on end of each solenoid (1) lead.
3. Insert pins (2) into housing (3) with HOLD wire
in position 1, PULL wire in position 2, and C wire
in position 3.
4. Mark strap (4) with P14 and install in position
shown.
Figure D-12. Solenoid Assembly, Fuel (P/N: 88-20482)
D-12