ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
NOTES:
PROCEDURES:
1. Dimensions shown are in inches.
1. Cut wire (1) to length indicated.
2. Refer to TM 9-6115-641-24P for materials re-
2. Strip 0.75 inch of insulation from each end of
quired.
wire (1).
3. Position insulation sleeving (2) on center of wire,
mark with wire number100B2" and shrink to fit.
4. Crimp terminal (3) on one end of wire (1).
5. Crimp terminal (4) on other end of wire (1).
Figure D-2. Cable Assembly, Battery (P/N: 88-20313)
D-3