TM 55-6115-491-40
u. Install the grommet (32) in the spacer ring
w. Position the electrical generator cover (16)
(33). Position the terminal board (29) on the spacer ring
on the spacer ring (33); secure the air scoop and spacer
(33) so that the (+) terminal is in alignment with terminal
ring to the brush support assembly (66) with five screws
T4 on AC block and lettering is toward anti-drive end.
(17) and flat washers (18).
x. Position the electrical contact cover (5) on
Secure with two screws (30) and flat washers (31).
Position the spacer ring on the bearing support.
the generator assembly; secure with five screws (6), lock
v. Position a washer (28) on each of the studs
washers (7), and flat washers (8).
y. If the identification data plate (1) or
of the terminal board and position the lug terminals (27)
of the stator leads on the terminal board; secure with
maintenance name plate (3) was removed, install a new
nuts (24), lock washers (25), and flat washers (26).
plate. The plate must indicate counterclockwise rotation
when viewed from the drive end.
3-19