TM 55-6115-491-40
Figure 4-4. Dimensions for Brush Support Lip Slot.
4-9. PM Generator No-load AC Sensing Voltage Test.
b. Increase the generator speed to 8, 500 RPM.
a. Operate the generator at 8, 000 RPM no load.
The no-load DC voltage at this speed shall be 42 volts
b. Check the AC voltage between terminals P1
maximum.
and PN. The AC output shall be 10 volts minimum.
4-10. PM Generator No-load Voltage Test.
PM generator output. It should be as shown in figure 4-
6.
a. Operate the generator at 8, 000 RPM at no
4-11. PM Generator Full-load Voltage Test.
load. Check the DC voltage output across the +and --
a. Connect a resistive load of 4.0 t 0.2 ohms
terminals. The no-load DC output shall be 34 volts
minimum.
4-4