ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
c.
Testing.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Release lug cover by turning two fasteners, open lug cover.
(4) Disconnect load cables from EMI filter load terminals as necessary.
(5) Tag and disconnect two female quick-disconnects connected to bottom terminals
(6) Tag and disconnect one wire lead connected to "L" terminal and four wire leads
connected to "N" terminal on EMI filter.
(7) Using multimeter set for ohms, check for open circuit across two upper EMI filter
terminals "L" and "N". If not open, EMI filter is defective.
(8) Repeat step (7) for "L" and "N" terminals that connect to the GFCI convenience
receptacle (lower).
(9) Using multimeter set for ohms, check for closed circuit across the lower "L" terminal
(that connects to GFCI convenience receptacle) and load terminal "L". If not
closed, EMI filter is defective.