ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
(3) If removed, install operating instructions plate on lug cover with new rivets.
(4) Install lug cover on control panel with new rivets.
(5) Close and secure lug cover.
EMI FILTER (MEP-531A).
a.
Inspection.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Release lug cover by turning two fasteners, open lug cover.
(4) Inspect load terminals of EMI filter for deformed threads, corrosion, and other
physical damage.
(5) Ensure connections to EMI filter inside of the control box are clean and tight.
Clean and tighten if necessary.
(6) Close and secure instrument panel.
(7) Close and secure lug cover.
b.
Removal.
(2) Release lug cover by turning two fasteners, open lug cover.
(3) Disconnect load cables from EMI filter load terminals as necessary.
(4) Release instrument panel by turning fastener, open instrument panel slowly.
(5) Tag and disconnect two female quick-disconnects connected to bottom terminals
(6) Tag and disconnect one wire lead connected to "L" terminal and four wire leads
connected to "N" terminal on EMI filter.
(7) Remove screws, washers, lockwashers, and nuts securing bottom of EMI filter to
control box. Note how instrument panel ground strap and wiring cable clamp are
captured under the mounting hardware.
(8) Remove nuts, lockwashers, and washers securing top of EMI filter to control box.
(9) Remove EMI filter.