ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
Table 4-20. No
Output From Alternator Troubleshooting (MEP-531A)
No output from
OK
Not OK
connector (P1) is connected to
control panel receptacle J2
Test for defective ON-OFF
Connect alternator
OK
Not OK
load circuit breaker (CB1)
harness connector (P1)
Replace defective ON-OFF
Not OK
OK
FL1-N,
load circuit breaker (CB1)
FL1-N
E, and
CB1-B(LOAD)
FL1-L
Remove and inspect for
OK
Repair or replace
defective brushes,
defective wiring
Not OK
OK
Test for defective EMI filter (FL1),
Not OK
Contact next higher
Replace EMI filter (FL1),
maintenance level