ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
Table 4-23. Cannot Adjust Alternator Output With VOLTAGE ADJ. Potentiometer
Troubleshooting
with VOLTAGE ADJ.
potentiometer (R2)
Inspect for broken or corroded
OK
Not OK
connections at VOLTAGE ADJ.
potentiometer (R2)
Not OK
OK
Clean and tighten connectors
R2
TB1-12 and R2
TB1-11
(MEP-531A) or R2
TB1-13 and
R2
TB1-12 (MEP-501A)
Test for defective
Not OK
Repair or replace
OK
VOLTAGE ADJ. potentiometer
defective wiring
Replace defective
Contact next higher
VOLTAGE ADJ. potentiometer
maintenance level.