ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
FUEL LINE
TUBING
FITTING
CLAMP
CLAMP
FITTING
NOTE
If removing tank-to-filter fuel line tubing, fuel tank must be
drained.
(2) If necessary, open fuel tank drain cock (Figure 4-14) and drain fuel into suitable
container. Close fuel tank drain cock. Fuel tank capacity is 1.6 gal. (6.1 L).
(3) Loosen hose clamps (Figure 4-12) and remove fuel line tubing.
(4) Remove fittings as necessary.
b.
Installation.
(2) Install fuel line tubing and tighten clamps.
(3) If drained, fill fuel tank with diesel fuel (DL-1, DL-2, or JP-8).
FUEL FILTER ASSEMBLY.
NOTE
For generator sets with the original Mechron configuration fuel
filter assembly, replace entire assembly with the assembly
listed in this manual. Shorten fuel line from fuel tank to fuel
filter assembly by approximately two (2) inches to reduce slack
in fuel line.