a.
Install ground wire (8) in terminal block (7) and torque screw (6) to 45 in-lb (5.1 Hm).
b.
Install three leads (2) in terminal block (5) and tighten screws (4) in accordance with the torque specifications
shown in Appendix H).
c.
Install three leads (2) in 400-amp circuit breaker (3) and torque screws (1) to 275 in.-lb (31.4 Nm). Remove tags.
5-19