TM 9-6150-228-13&P
5-13
CABLE ASSEMBLIES.
(4) Set up crimper for foot operation as follows:
(a) Install plug in rear of crimper handle.
(b) Apply thread sealant to, and install, the 1/4-inch NPT coupler in center of rear casing. Tighten coupler.
(c) Install the male, quick-disconnect fitting in coupler. Tighten coupler.
(d) Install air hose between foot pedal and quick-disconnect fitting in rear of casting.
(e) Install air hose from regulator onto foot control pedal.
Misuse of compressed air could result in death or serious injury. When working with air,
always use eye protection and any other protective equipment.
(5) Open valve on air tank and adjust regulator to approximately 1 00 psi.
NOTE
When regulator valve is opened, the button on the front of the crimper handle will pop
out if the crimper is set up for hand operation. If the crimper is set up for foot control,
the button on the handle will not pop out.
(6) Turn the regulator valve to the on position.
(7) Refer to Appendix G and select the proper size locator and die to be used. This is determined by the size of
the pins or sockets being installed.
(8) Remove the retaining ring (1) from the front of the crimping tool and install locator (2), taking care to align
notches in locator with notches in crimper.
NOTE
When properly installed, locator will be flush with retainer face.
(9) Align pin (3) on crimper with hole (4) on back of die (5) and install die.
5-28