TM 9-6115-729-24
DIRECT SUPPORT (FIELD) LEVEL MAINTENANCE
TACTICAL QUIET GENERATOR 100 kW, 50/60 Hz MEP-807A/PU-807A
FLYWHEEL MAINTENANCE
INITIAL SETUP:
Tools and Special Tools
Personnel Required
Shop Equipment, Automotive Maintenance,
Two
References
Materials/Parts
TM 9-6115-729-24P
Breakthrough cleaning solvent (WP 0120, Item 47)
WARNINGS
Metal jewelry will conduct electricity. All jewelry can become entangled in generator set
components. Remove all jewelry when working on generator set. Failure to comply can cause
injury or death to personnel by electrocution.
DO NOT wear loose clothing when performing checks, services and maintenance. Failure to
comply can cause injury or death to personnel.
High voltage is produced when this generator set is in operation. Make sure unit is completely shut
down and free of any power source before attempting any repair or maintenance on the unit.
Failure to comply can cause injury or death to personnel.
High voltage is produced when the generator set is in operation. Never attempt to start or
maintain the generator set unless it is properly grounded. Failure to comply can cause injury or
death to personnel.
REMOVAL
WARNING
Flywheel weighs more than 50 pounds (23 kg) and requires a two-person lift. Lifting flywheel can
cause back strain. Ensure proper lifting techniques are used when lifting flywheel. Failure to
comply can cause injury to personnel.
1. Remove top bolt (Figure 1, Item 1) and washer (Figure 1, Item 2).
2. Install guide bolt that is longer than the top bolt (Figure 1, Item 1) to assist in removal of flywheel (Figure 1,
Item 3).