TM 9-6115-729-24
0097
INSTALLATION - Continued
8. Carefully position electrical component mounting brackets assembly (Figure 1, Sheet 1, Item 10) over
generator (Figure 1, Sheet 1, Item 11) and onto engine generator frame.
9. Install two washers (Figure 1, Sheet 1, Item 9), lockwashers (Figure 1, Sheet 1, Item 8), and screws (Figure 1,
Sheet 1, Item 7).
10. Install two washers (Figure 1, Sheet 1, Item 6), lockwashers (Figure 1, Sheet 1, Item 5), and screws (Figure 1,
Sheet 1, Item 4).
11. Remove tags and route generator cables through current transformers (Figure 1, Sheet 1, Item 3).
12. Remove tags and connect two generator field leads G1-F2 and G1-F1 to terminal board TB5-1 and -2 (Figure
1, Sheet 1, Item 2 and FO-3, sheet 1).
13. Remove tags and connect ten generator cables T1 thru T10 to reconnection board TB1 (Figure 1, Sheet 1,
Item 1).
16. Install rear section housing assembly (WP 0034).
17. Install engine generator compartment ceiling assembly (WP 0031).
18. Install rear roof section housing assembly (WP 0030).
19. Install front roof section housing assembly (WP 0029).
20. Install right rear door assembly (latch) (WP 0027).
22. Install left rear door assembly (latch) (WP 0023).
END OF TASK
END OF WORK PACKAGE
0097-6