ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
d.
Installation.
(1) Install terminal board (Figure 4-38) in control panel with washers, lockwashers, and
screws.
(2) Connect bus (MEP-531A) and electrical leads to terminal board. Remove tags.
(4) Close and secure instrument panel.
LOAD TERMINAL BOARD. (MEP-501A AND MECHRON SETS).
a.
Inspection.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Release lug cover by turning two fasteners, open lug cover.
(4) Inspect load terminal board for security, cracks, deterioration, or other physical
damage. Replace if defective.
(5) Close and secure instrument panel.
(6) Close and secure lug cover.
b.
Removal.
(3) Remove nut (5, Figure 4-39), lockwashers (6), washers (7) and electrical wiring
with p-clamp (3) from screw (8).
(4) Remove locknut (2), washers (7), lockwasher (6), ground strap (4), and nut (5) from
screw (9).
(5) Remove nuts (5), lockwashers (6), washers (7), screws (10), and load terminal
board (1) from control panel.
c.
Installation.
(1) Install load terminal board (1, Figure 4-39) on control panel with screws (10),
(2) Install washers (7), lockwasher (6), nut (5), ground strap (4) and locknut (2) on
screw (9).