Table 4-1. Unit Preventive Maintenance Checks and Services (Continued)
M-Monthly
Q-Quarterly
S-Semi-annually
A-Annually
B-Bi-annually
H-Hourly
(1)
(2)
(3)
(4)
(5)
Interval
Item
Item To Be
Equipment Is Not
M
Q
S
A
B
H
No.
Inspected
Procedure
Ready/Available If:
(21)
Load Terminal
Check for damaged or
Damaged or corroded load
Board (MEP-
corroded load terminals, load
terminals, terminal board, or
EMI filter load terminals.
501A and
terminal board, and EMI filter
Mechron Sets)
load terminals.
Damaged or missing
EMI Filter (MEP-
Check for damaged or
retaining clips.
531A)
missing retaining clips.
(22)
Check ground strap for
Damaged ground strap.
damage.
(23)
Low Oil Pressure
Check for damaged push-pull Damaged or misadjusted
(LOP) Engine
cable and tube. Check cable LOP engine shutdown cable.
Shutdown Cable
adjustment. Refer to
(24)
Air Preheater Lead
Check for damaged or
Damaged air preheater lead.
missing tubing and protective
boot; damaged or burned
wires and insulation.
(25)
Engine Wiring
Check for damaged, missing,
Damaged, missing, or
Harness
corroded clamps; damaged
corroded engine wiring
or missing tubing and
harness components.
protective boot; and burned
insulation.
(26)
Check for damaged, missing,
Damaged, missing, or
Harnesses
corroded clamps; damaged
or missing tubing and
harness components.
protective boot; and burned
insulation.
(27)
2000
Resilient Mounts
Replace resilient mounts
after 2000 hours. Refer to
(28)
Frame
Check for damage and
Damaged or corroded frame.
corrosion.
(29)
Fuel System
Check for damaged or
Damaged or corroded
corroded fuel tank brackets
components.
and guard.
(30)
Check for damaged,
Damaged or corroded
components.
brackets, engine mounting
bracket, and fuel filter
stiffener.
(31)
Air Intake System
Check for damaged or
Damaged or corroded air
corroded air filter plate and
intake components.
air filter cover.
4-12