TM 9-6115-664-13&P
4-19. APU MOUNTING BRACKET MAINTENANCE
This task covers removal, inspection, testing, and installation
INITIAL SETUP
Tools:
Equipment Condition:
Shop Equipment, Automotive Maintenance
APU Shut Down
and Repair (Item 1, App. B)
NATO Plug Disconnected
Parts/Materials:
Anti-Seize Compound (Item 14, App. E
A. REMOVAL.
NOTE
Discard and replace all lockwashers
and locknuts when removed.
1.
Remove APU mounting bracket (1, Figure 4-9) from
left side panel by removing bolts (2), lockwashers
(3), and washers (4).
2.
Remove mounting bracket (5) from right side panel
by removing bolts (6), lockwashers (7), and
washers (8).
B. INSPECTION.
Inspect brackets and side panels for dents, cracks,
or damage. Inspect painted surfaces for chips,
scratches, bare metal, or corrosion.
C. INSTALLATION.
1.
Apply anti-seize compound to bolts (2). Install
mounting bracket (1) to left side panel using bolts
(2), lockwashers (3), and washers (4).
2.
Apply anti-seize compound to bolts (6). Install
mounting bracket (5) to right side panel using bolts
(6), lockwashers (7), and washers (8).
3.
Connect NATO plug to receptacle and secure using
strap.
Figure 4-9. APU Mounting Brackets
4-52