TM 9-6115-664-13&P
4-15. NOSEPIECE ASSEMBLY MAINTENANCE
C.
REPAIR.
1.
Repair painted and stenciled surfaces in accordance with Para. 4-11.
2.
Repair of parts, other than painting, is limited to removal and replacement of damaged components.
D.
INSTALLATION.
1.
Mate insulation to rear of nosepiece assembly (1, Figure 4-5) and secure using new caps.
2.
Apply a thin bead of silicon adhesive to lip at top of nosepiece (1) that mates with enclosure. Apply adhesive to top 3
inches of lip on each side of nosepiece as well.
3.
Mate nosepiece assembly (1) to brackets (2) and secure using six screws (3), lockwashers (4), and washers (5).
4.
Connect NATO plug to receptacle and secure using strap.
4-47