i.
j.
k
2-45-3
a.
b.
c.
d.
e.
f.
2-45-4
a.
b.
c.
d.
e.
f.
ARMY TM 9-6115-644-24
AIR FORCE TO 35C2-3-448-12
MARINE CORPS TM 09249A/09246A-24/2
Connect electrical leads to switch (14) and remove tags.
Install control box top panel, paragraph 2-15-4.
Connect negative battery cable and dose battery access door.
Removal.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Remove control box top panel, paragraph 2-15-1.
Tag and disconnect electrical leads from FREQUENCY SELECT switch (14, FIGURE 2-14).
Tag and remove resistor (11) from FREQUENCY SELECT switch (14).
Remove nut (12), Iockwasher (13), and FREQUENCY SELECT switch (14).
Position FREQUENCY SELECT switch (14, FIGURE 2-14) in mounting bracket.
Install lockwasher (13) and nut (12).
Install resistor (11) on FREQUENCY SELECT switch (14) and remove tags.
Connect electrical leads amd remove tags.
Install co ntrol box top panel, paragraph 2-15-4.
Connect negative battery cable and close battery access door.
Installation.
2-46
CONVENIENCE RECEPTACLE.
2-46-1
a.
b.
c.
d.
2-46-2
a.
b.
c.
d.
e.
f.
Inspection.
Shut down generator set.
Inspect CONVENIENCE RECEPTACLE for cracks, breaks, corrosion, bent terminals, or other indications of
damage.
Inspect cover for cracks, corrosion, or damaged springs.
Replace defective parts.
Testing.
Shut down generator set.
Remove control box top panel, paragraph 2-15-1.
Tag and disconnect CONVENIENCE RECEPTACLE (20, FIGURE 2-14) electrical leads.
Set multimeter for ohms and check for continuity between upper side terminals and lower side terminals of each
plug outlet.
Replace CONVENIENCE RECEPTACLE if continuity is not indicated between terminals.
Connect electrical leads to receptacle (20) and remove tags.
2 - 8 1