ARMY TM 9-6115-641-10
AIR FORCE TO 35C2-3-456-11
2-6 PMCS PROCEDURES - Continued.
TABLE 2-4.
Item
Number
14
15
16
Internal
Before
Before
Before
Operator Preventive Maintenance Checks and Services - Continued
Location
Item to be
Check/Service
Exhaust/
Intake System
Exhaust
System
Air Cleaner
Assembly
Grounding
Rod Assembly
Ground Rod
Cable and
Connections
Procedure
WARNING
Exhaust discharge contains deadly
gases. DO NOT operate generator
set in an enclosed areas unless
exhaust discharge is vented outside.
Severe personal injury or death due
to carbon monoxide poisoning could
occur.
Inspect for leaks, corrosion, and
missing parts.
Inspect for loose, damage, or missing
parts
Inspect restriction indicator for
clogged air cleaner element.
WARNING
NEVER attempt to start the generator
set if it is not properly grounded.
Personal injury or death due to
electrocution may result.
Inspect for damage, corrosion, and
loose connections.
Not Fully Mission
Capable if:
Leaks, damaged,
or missing parts.
Loose or missing
parts.
Clogged air
cleaner element.
Damaged,
corroded or loose
connections
2-11