ARMY TM 9-6115-641-10
AIR FORCE TO 35C2-3-456-11
2-6
Table 2-4. Operator Preventive Maintenance Checks and Services - Continued
Item
Number
5
6
7
8
9
10
11
12
13
Interval
Before
Before
Before
Before
Before
Before
Before
Before
Before
Item to be
Check/Service
Engine Assembly
Fuel System
Fuel Filter/Water
Separator
Lubrication System
Cooling System
Radiator
Hoses
Cooling Fan
Fan Belt
Overflow Bottle
Procedure
The fuels used in this genera-
tor set are highly explosive.
DO NOT smoke or use open
flame when performing main-
tenance. Flames and expli-
sion can occur resulting in
severe injury or death.
Inspect for loose, damaged, or missing
hardware.
Inspect for leaks, damage, loose, or missing
hardware.
Inspect for leaks, cracks, damage, proper
mounting, loose or missing parts.
Drain water from fuel filter/water separator.
Ref (3-3.6.2)
Inspect for leaks, damage, loose or missing
parts.
Inspect oil level.
Inspect for contamination.
WARNING
Cooling system operates at
high temperatures. Personal
injury or death from burns or
scalding can result from con-
tact with high pressure
steam and/or Iiquid.
Inspect for leaks, damage, loose or missing
parts.
Inspect for leaks, cracks, or missing parts.
Inspect for obstruction, damage, or loose-
ness.
Inspect for unusual noise in fan area.
Inspect for cracks, fraying, or looseness.
Inspect for proper mounting, leaks, or mis-
sing hardware.
Any loose, dam-
aged, or missing
hardware.
Any fuel leaks, dam-
age, loose or missing
parts.
Any fuel leak
Water not drained.
Class Ill leeks, dam-
age, loose or missing
parts.
oil level is low.
Oil shows signs of
contamination.
Class Ill leaks of mis-
sing radiator cap.
Class Ill leaks or mis-
sing damps or hoses.
Damaged or loose.
Unusual noise from
area.
Broken or missing
belt.
Class Ill leaks or mis-
sing hardware.
2-10 Change 1