ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
Table 2-1. Operator Preventive Maintenance Checks and Services for MEP 831A / 832A (continued)
Item
No.
Interval
Location:
Item to
Check/
Service
Procedure
Not Fully Mission
Capable If:
18
During
(After 8
hours of
continual
use)
Engine oil
WARNING:
Never service generator set while engine is
running. Shut down unit before servicing oil.
Injury to personnel can occur if proper
procedures are not followed.
a. Shut down generator set. Open enclosure
cover.
b. Remove engine oil fill cap and check oil
level. Service as required in accordance
with para. 3-1.
Oil level is at or
below minimum oil
level mark on
dipstick.
19
During
(After 8
hours of
continual
use)
Fuel filter / water
separator
WARNING:
Never service generator set while engine is
running. Shut down unit before draining filter
separator. Injury to personnel can occur if
proper procedures are not followed.
a. Shut down generator set. Open enclosure
cover.
b. If water is present, drain water from fuel
filter / water separator by turning valve.
Water and fuel are
mixed. Separator is
damaged or leaking.
2-17
Change 1