ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
Table 2-1. Operator Preventive Maintenance Checks and Services for MEP 831A / 832A (continued)
Item
No.
Interval
Location:
Item to
Check/
Service
Procedure
Not Fully Mission
Capable If:
11
Before
Skid base
a. Inspect oil and fuel drain ports for damage.
Ensure drain plugs are securely attached.
b. Inspect lifting handles and tie down rings
for damage. Check security of attachment.
c. Inspect engine vibration mounts for
cracks, wear, or deterioration.
Drain ports are dam-
aged to the extent they
will leak.
Lifting handles do not
operate or are loose.
Vibration mounts are
damaged or worn.
12
Before
Battery
a. Open enclosure cover, inspect battery
cables for corrosion, evidence of
electrical short, and obvious damage.
Check for cuts, tears, or exposed wires.
b. Inspect battery terminals and battery posts
for corrosion and damage. Check for
security of attachment and that the battery
terminal
quick
release
feature
is
functional.
c. Inspect battery for cracks, corrosion, or
evidence of leakage.
NOTE: A battery that
will not provide
power to the electrical
starter motor or that is
missing does not
make the generator
Not Mission Capable.
Notify next higher
level of maintenance.
2-15
Change 1