ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-33. OUTPUT TERMINALS AND EMI FILTER MAINTENANCE - cont.
Figure 4-24. Output Terminals / Filter
(Sheet 3 of 4)
C. INSTALLATION.
1.
Install load terminals (10, Figure 4-24) using nuts (12) and washers (13). Install ground terminal (11,
lower right hand hole) using nut (14) and washers (13).
2.
Mate load board (15) to generator set skid base. Secure using four screws (16), washers (17), and locknuts
(18).
3.
Install EMI filter (9) onto load and ground terminals (10, 11). Secure using four nuts (7) and washers (8).
Connect EMI filter connectors.
4.
Connect electrical cables to load and ground terminals (10, 11) using load wrench. Neutral terminal is
upper right. Ground terminal is lower right.
4-68