ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-33. OUTPUT TERMINALS AND EMI FILTER MAINTENANCE
This task covers removal, inspection, and installation.
INITIAL SETUP
Tools:
Equipment Condition:
Tool Kit, General Mechanics Automotive
Generator set shut down (Para. 2-9)
(Item 2, App. B, Sect. III)
Battery cables disconnected
Cable disconnected for SLAVE RECEPTACLE
A. REMOVAL.
1.
Unlock generator set enclosure cover latches and
lift cover to open.
2.
Turn lock (2, Figure 4-24) and open output panel
cover (1).
3.
Disconnect load and ground wires from load
terminals using load wrench (3).
4.
Release load wrench (3) lanyard from output box
by removing screw (4), washer (5), and locknut
(6). Remove lanyard from wrench only if
replacement is required.
5.
Tag and disconnect EMI filter (9) electrical
connectors. Remove EMI filter from load and
ground terminals (10, 11) by removing four nuts
(7) and washers (8).
6.
Remove load board (15) from generator set skid
base by removing four screws (16), washers (17),
and locknuts (18).
7.
Remove load terminals (10) by removing nuts
(12) and washers (13). Remove ground terminal
(11) by removing nut (14) and washers (13).
Figure 4-24. Output Terminals / Filter
(Sheet 1 of 4)
4-66