ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-26. GOVERNOR CONTROL MAINTENANCE
This task covers removal, inspection, and installation.
INITIAL SETUP
Tools:
Equipment Condition:
Tool Kit, General Mechanics Automotive
Generator set shut down (Para. 2-9)
(Item 2, App. B, Sect. III)
Battery cables disconnected
Cable disconnected for SLAVE RECEPTACLE
A. REMOVAL.
1.
Turn quarter-turn fasteners to unlock and open
control panel.
2.
Tag and disconnect electrical wiring from
governor control (1, Figure 4-17).
3.
Remove governor control (1) from inside wall of
control box by removing screw and captive
washer assemblies (2).
B. INSPECTION.
1.
Inspect governor control for corrosion, evidence
of electrical short, and obvious damage.
2.
Inspect electrical wiring for cuts, crimps, bare
wire, or other damage. Ensure connectors are
securely attached.
3.
Remove and replace any component that is
damaged to the extent that it will effect the safe
operation of the generator set.
Figure 4-17. Governor Control
C. INSTALLATION.
1.
Mate governor control (1, Figure 4-17) to inside
wall of control box. Secure using screws and
captive washer assemblies (2).
2.
Connect electrical wiring to governor control (1).
3.
Close control panel and lock in place using
quarter-turn fasteners.
4-52