ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-29. BATTERY CHARGING REGULATOR MAINTENANCE
This task covers removal, inspection, and installation.
INITIAL SETUP
Tools:
Equipment Condition:
Tool Kit, General Mechanics Automotive
Generator set shut down (Para. 2-9)
(Item 2, App. B, Sect. III)
Battery cables disconnected
Cable disconnected for SLAVE RECEPTACLE
A. REMOVAL.
1.
Turn quarter-turn fasteners to unlock and open
control panel.
2.
Unlock main access cover latches and lift cover to
open.
3.
Disconnect electrical plug from battery charging
regulator (1, Figure 4-20).
4.
Remove battery charging regulator (1) from top
of control box by removing screws (2), washers
(3), and locknuts (4).
B. INSPECTION.
1.
Inspect battery charging regulator for corrosion,
evidence of electrical short, and obvious damage.
2.
Inspect electrical wiring for cuts, crimps, bare
wire, or other damage. Ensure terminal lugs are
securely attached.
3.
Remove and replace any component that is
damaged to the extent that it will effect the safe
operation of the generator set.
Figure 4-20. Battery Charging Regulator
4-58