ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
C. INSTALLATION.
1.
Configuration A: Install microswitch (8, Figure 4-19) onto AAC circuit interrupter contactor K1 (4) using
screw and captive washer assemblies (7).
2.
Configuration A: Mate contactor K1 (4) and bracket (9) to back of control box. Secure using screw and
captive washer assemblies (5) and washers (6).
Configuration B: Mate contactor K1 (4) to back of control box. Secure using screw and captive washer
assemblies (5) and washers (6).
3.
Connect electrical wiring to contactor K1 (4).
4.
Configuration A: Install protective plate (1) onto bracket (9) using screws (2) and lockwashers (3).
Configuration B: Install protective plate (1) onto contactor K1 (4) using screws (2) and lockwashers (3)
5.
Close main access cover and lock in place using latches.
Figure 4-19. AC Circuit Interrupter Contactor
4-57
Change 1