ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-30. CONVENIENCE RECEPTACLE MAINTENANCE (60 HZ, MEP 831A ONLY)
This task covers removal, inspection, and installation.
INITIAL SETUP
Tools:
Equipment Condition:
Tool Kit, General Mechanics Automotive
Generator set shut down (Para. 2-9)
(Item 2, App. B, Sect. III)
Battery cables disconnected
Cable disconnected for SLAVE RECEPTACLE
A. REMOVAL.
1.
Unlock main access cover latches and lift cover to
open.
2.
Remove screw (1, Figure 4-21) to disconnect
receptacle cover (2) from convenience receptacle
(3). Remove cover and rubber gasket (6) by
removing four screw and captive washer
assemblies (4).
CAUTION
Ensure wire leads on receptacle terminals
are not damaged when pulling on
receptacle.
3.
Remove convenience receptacle (3) from control
box by removing two screws (5).
4.
Tag and disconnect electrical wiring from the rear
of convenience receptacle (3).
B. INSPECTION.
1.
Inspect convenience receptacle for corrosion,
evidence of electrical short, and obvious damage.
Check terminal connectors for damage.
Figure 4-21. Convenience Receptacle
4-60