ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-24. CONTROL BOX RELAY MAINTENANCE - cont.
C. INSTALLATION.
1.
Mate relay sockets (1, Figure 4-15) to rear wall of control box. Secure using screws (2) and nuts (3).
2.
Connect electrical wiring to relays K12, K14, and K15.
3.
Insert relays (3) into relay sockets (1). Secure using holdown springs (4).
4.
Close control panel and lock in place using quarter-turn fasteners.
4-49