TM 9-6115-730-24
UNIT (FIELD) LEVEL MAINTENANCE
TACTICAL QUIET GENERATOR 200 kW, 50/60 Hz MEP-809A/PU-809A
RADIATOR ASSEMBLY MAINTENANCE
INITIAL SETUP:
Tools and Special Tools
References
Shop Equipment, Automotive Maintenance,
TM 750-254
TM 9-6115-730-24P
Tool Kit, General Mechanic's (WP 0123, Item 1)
Equipment Condition
Materials/Parts
Front roof section housing assembly removed
Rear roof section housing assembly removed
Personnel Required
Engine generator compartment ceiling assembly
Two
Fan guards, shrouds, and upper and lower
Right front door assembly (latch) removed
WARNINGS
Metal jewelry will conduct electricity. All jewelry can become entangled in generator set
components. Remove all jewelry when working on generator set. Failure to comply can cause
injury or death to personnel by electrocution.
DO NOT wear loose clothing when performing checks, services and maintenance. Failure to
comply can cause injury or death to personnel.
High voltage is produced when this generator set is in operation. Make sure unit is completely shut
down and free of any power source before attempting any repair or maintenance on the unit.
Failure to comply can cause injury or death to personnel.
High voltage is produced when the generator set is in operation. Never attempt to start or
maintain the generator set unless it is properly grounded. Failure to comply can cause injury or
death to personnel.
DC voltages are present at generator set electrical components even with generator set shut
down. Avoid shorting any positive with ground/negative. Failure to comply can cause injury to
personnel and damage to equipment.
0068-1