TM 9-6115-730-10
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM
ITEM TO
MISSION
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
WARNING
Fuel System
Continued
When running, winterization heater has
hot metal surfaces that will burn flesh
and allow heater to cool before
performing maintenance. Wear gloves
and additional protective clothing as
required. Failure to comply can cause
injury or death to personnel.
NOTE
If the TQG is operating continuously, do
the DURING PMCS checks every four
hours.
Inspect fuel system for leaks, damaged,
Any fuel leaks,
loose or missing parts.
damaged, loose or
missing parts.
36
During
Lubrication System
Inspect lubrication system for leaks,
Class III leaks.
damaged, loose or missing parts.
Damaged, loose or
missing parts.
Oil level is below hot
add oil mark on
dipstick.
COOLING
SYSTEM
37
During
Cooling fan
__________
WARNING
Cooling system operates at high
temperature and pressure. When
performing DURING PMCS, wear
gloves and additional protective
clothing and goggles as required.
Contact with high pressure steam
and/or liquids can result in burns and
scalding.
Check for unusual noise being emitted from
Cooling fan is
fan area.
damaged or loose.
38
During
Overflow Bottle
Check coolant level between COLD and
Coolant level is below
HOT lines in overflow bottle
COLD line.
0012 00-12