TM 9-6115-730-10
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM
ITEM TO
MISSION
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
Electronic Modular
Control Panel
(EMCP)
52
After
Indicators and
Check all indicators and controls for
Indicators or controls
Controls
damaged or missing parts.
damaged or
missing.
53
After
Indicators and
Check all indicators and controls for
Indicators or controls
Controls
damaged or missing parts.
damaged or
missing.
54
After
Overall Exterior
Check external doors, panels, hinges, and
Cannot shut doors.
latches for damaged, loose or corroded
items.
CAUTION
Operating the generator set with
restricted airflow for cooling can cause
access door inlet panels clear to ensure
maximum airflow for engine and
generator cooling. Failure to comply
can result in poor engine performance
and possible overheating and automatic
shutdown.
Inspect air intake and exhaust grills for
Any restrictions of air
debris.
flow or cannot clear
debris.
PU-809A TRAILER
INSTALLATION
55
After
Accessory Box
Inspect accessory box clamping hasp for
operation.
Check accessory box contents to ensure that
Ground rod and
all required items are present and
components are
serviceable.
missing or
unserviceable.
END OF TASK
0012 00-16