TM 9-6115-730-10
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM
ITEM TO
MISSION
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
__________
9
Before
Ether Start System
WARNING
Breathing ether fumes can cause
fainting. Do not manually discharge or
deliberately inhale ether. Failure to
comply can cause injury to personnel.
Check for deteriorated, loose, or missing
Ether bottle missing
parts.
with temperatures
below 10F (12C)
10
Before
Lubrication System
Inspect lubrication system for leaks,
Class III leaks.
damaged, loose or missing parts.
Damaged, loose or
missing parts.
Oil level is below cold
(low) oil level mark
on dipstick.
Engine oil is milky,
discolored, or shows
signs of
COOLING
SYSTEM
__________
11
Before
Radiator
WARNING
Cooling system operates at high
temperature and pressure. Contact
with high pressure steam and/or liquids
can result in burns and scalding. Shut
cool before performing checks, services
and maintenance. Failure to comply
can cause injury or death to personnel.
Check radiator for leaks, damage or missing
Class III leaks.
parts.
Coolant fill cap
missing or
damaged.
12
Before
Fan Guards
Check fan guards and shroud for dirt and
Dirt or debris block
debris blocking air flow.
air flow.
13
Before
Hoses
Check hoses for leaks or cracks.
Class III leaks.
0012 00-6