TM 9-6115-730-10
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM
ITEM TO
MISSION
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
Ensure that acoustical materials are securely
5
Before
Acoustical Materials
in place, free of damage or not missing.
ENGINE
COMPARTMENT
__________
WARNING
DC voltages are present at generator set
6
Before
Engine Assembly
electrical components even with
generator set shut down. Avoid
shorting any positive with ground/
negative. Failure to comply can cause
injury to personnel and damage to
equipment.
Hardware loose,
Check for loose damaged or missing
damaged, or
hardware.
missing.
__________
7
Before
Fuel System
WARNING
flammable. Do not smoke or use open
flames when performing maintenance.
Failure to comply can result in flames
and possible explosion and can cause
injury or death to personnel and
damage to the generator set.
Inspect fuel system for leaks, damaged,
Any fuel leaks,
loose or missing parts.
damaged, loose or
missing parts.
If using auxiliary fuel source, check for
Any fuel leaks,
leaks, damaged, loose or missing parts.
damaged, loose or
missing parts.
8
Before
Fuel Filter/Water
Inspect fuel filter/water separator for leaks,
Any fuel leaks,
Separator
proper mounting, cracks, damage, or
cracks, or missing
missing parts.
parts.
Drain water from fuel filter/water separator
Fuel filter/water
separator contains
sediment and/or
water or cannot be
drained.
0012 00-5