TM 9-6115-729-10
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM TO
MISSION
ITEM
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
Cannot shut doors.
52
After
Overall Exterior
Check external doors, panels, hinges, and
latches for damaged, loose or corroded
items.
CAUTION
Operating the generator set with
restricted airflow for cooling can cause
access door inlet panels clear to ensure
maximum airflow for engine and
generator cooling. Failure to comply
can result in poor engine performance
and possible overheating and automatic
shutdown.
Any restriction of air
Inspect air intake and exhaust grills for
flow or cannot clear
debris.
debris.
53
After
Accessory Box
Inspect accessory box clamping hatch hasp
for operation.
Ground rod and
Check accessory box contents to ensure that
components are
all required items are present and are
missing or
serviceable.
unserviceable.
END OF TASK
0012 00-16