TM 9-6115-729-10
0014 00
ENGINE AIR CLEANER MAINTENANCE Continued
SERVICE
1.
On EMCP, set ENGINE CONTROL switch to OFF/RESET.
2.
Set DEAD CRANK SWITCH to OFF.
3.
Set Battery Disconnect Switch to OFF.
4.
Open access doors at left rear of generator set housing to access air cleaner.
5.
Unlatch three latches (4) and remove air cleaner end cap (2) from air cleaner housing (1).
6.
Remove outer air cleaner element (5).
7.
Remove inner air cleaner element (6).
8.
Squeeze rubber dust cup (7) at bottom of end cap (2) extension several times to expel dust and debris.
9.
Inspect inside of air cleaner housing (1) for debris.
10. Wipe housing interior with clean lint-free cloth.
WARNING
Eye protection is required when working with compressed air. Compressed air can propel particles
at high velocity and injure eyes. Do not exceed 15 psi pressure when using compressed air. Failure
to comply could cause serious injury to personnel.
11. Clean inner air cleaner element (6) and outer air cleaner element (5) with compressed air or by tapping elements to
remove loose dirt.
12. Install inner air cleaner element (6), outer air cleaner element (5), and end cap (2) and secure three latches (4).
13. Reset restriction indicator (3) by pressing button on top of indicator. Red plunger will retract into body of indicator.
14. Close housing doors.
15. After operating TQG inspect restriction indicator (3) when performing DURING PMCS. If red plunger returns to clear
body of indicator, replace air filters.
END OF TASK
0014 00-2