TM 9-6115-729-10
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM TO
MISSION
ITEM
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
Inspect lubrication system for leaks,
45
After
Lubrication System
Class III leaks.
damaged, loose or missing parts.
Damaged, loose or
missing parts.
Oil level is below low
oil level mark on
dipstick.
COOLING
SYSTEM
__________
46
After
Radiator
WARNING
Cooling system operates at high
temperature and pressure. Contact
with high pressure steam and/or liquids
can result in burns and scalding. Shut
cool before performing checks, services,
and maintenance. Failure to comply
can cause injury or death to personnel.
Class III leaks.
Check radiator for leaks, damage or missing
Coolant refill cap
parts.
missing.
47
After
Hoses
Check hoses for leaks or cracks or loose
Class III leaks.
clamps.
48
After
Cooling Fan
Check fan for damage or looseness.
Cooling fan is
damaged or loose.
49
After
Fan Belts
Inspect belts to ensure that they are not
Broken, missing or
missing. Inspect for cracks, fraying, and
loose belt(s).
looseness.
50
After
Overflow Bottle
Check overflow bottle for cracks, leaks or
Class III leaks.
missing parts.
Coolant level is below
COLD line.
Electronic Modular
Control Panel
(EMCP)
51
Indicators and
Check all indicators and controls for
Indicators or controls
After
Controls
damaged or missing parts.
damaged or
missing.
0012 00-15