ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
LOCKWASHER
WASHER
FU
SE
FU
SE
CA
UT
ION
GROUND LEAD
120
VD
C
LOCKWASHER
CAPSCREW
NUT
WASHER
MOUNTING
BRACKET
SCREW
RESISTOR
WASHER
LOCKWASHER
LOCKNUT
LOCKNUT
c. Removal.
(2) Disconnect alternator wiring harness plug (Figure 4-61) from receptacle on bottom
of control panel.
(3) Remove capscrews, screws, lockwashers, washers and nut securing wiring
harness ground lead to alternator and wiring harness resistor to mounting bracket.
(4) Tag and disconnect wiring harness leads at alternator at four places.
(5) Cut cable ties as necessary and remove generator wiring harness.
d. Repair.
(1) Cut cable ties and flexible tubing as necessary.
(2) If replacing individual wires and/or connectors, tag and remove defective wires.
Then install new cable ties and tape flexible tubing as necessary and remove tags.
(3) If replacing the entire harness assembly, make new harness in accordance with