ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
(6) Reconnect transient suppressor assembly.
(7) Close and secure instrument panel.
d.
Repair. Repair transient suppressor assembly by assembling the transient suppressor
e.
Installation.
(1) Install transient suppressor assembly (Figure 4-30) on load terminals (+) and
(-)
with locknuts and washers.
(2) Close and secure instrument panel.
FUSEHOLDER (S).
a.
Inspection.
(2) Release instrument cover by turning fastener, open instrument cover.
(3) Release instrument panel by turning fastener, open instrument panel slowly.
(4) Inspect fuseholder for security, cracked cap, corrosion, and other damage.
(5) Inspect fuse for cracks and burned out element.
(6) Close and secure instrument panel and instrument cover.
b.
Removal.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Tag and disconnect electrical leads from fuseholder (Figure 4-31).
(4) Release instrument cover by turning fastener, open instrument cover.
(5) Remove nut.
(7) If necessary, remove cap and fuse.