ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
(10) If necessary, remove HERTZ frequency meter (MEP-531A only), VOLTS meter,
%LOAD meter, HOURS meter, VOLTAGE ADJ. potentiometer, GFCI receptacle
(MEP-531A only), and INST. fuseholders, refer to corresponding paragraphs.
(11) If necessary, remove rivets and instruction plate.
c.
Repair.
WARNING
CARC paint dust is a health hazard. Wear protective eyewear,
mask, and gloves when sanding CARC painted surfaces.
Failure to comply can cause personal injury.
(1) Repair all dents and cracks, and remove all loose paint.
(2) Remove light corrosion with fine grit abrasive paper (Item 16, Appendix E).
(3) Repaint surface in accordance with TM 43-0139/TO 35-1-3.
d.
Installation.
(2) If removed, install INST. fuseholders, GFCI receptacle (MEP-531A only),
VOLTAGE ADJ. potentiometer, HOURS meter, %LOAD meter, VOLTS meter, and
HERTZ frequency meter (MEP-531A only), refer to corresponding paragraphs.
(4) If removed, install edge protector (Figure 4-22) on control panel with contact
(5) If removed, install blind nut in control panel and fastener in instrument panel.
(6) If removed, install hinge on instrument panel with new rivets.
(7) Install instrument panel on control panel with new rivets.
(8) If removed, install ground strap on lug terminal board mounting screw and position
clamp on electrical harness.
(9) Secure ground strap and clamp to instrument panel with screw, washer,
lockwasher, and nut.
(10) Connect electrical leads to HERTZ frequency meter (MEP-531 only), VOLTS
meter, %LOAD meter, HOURS meter, VOLTAGE ADJ. potentiometer, GFCI
receptacle (MEP-531 only), and INST. fuseholder. Remove tags. Then install
gauge protective cover.
(11) Close and secure instrument panel.
4-71