SCOPE.
This section describes operator controls and indicators for the generator set.
CONTROLS AND INDICATORS.
Key
Control or Indicator
Function
1
Recoil Starter
When pulled, turns-over engine flywheel/crankshaft to start diesel engine.
2
Air Intake Cover
Directs airflow into the engine air intake system. In cold weather, the cover
is positioned to allow air which has been warmed by the hot muffler to flow
into diesel engine air intake system. Normally, the cover is positioned to
allow ambient air to flow into the diesel engine.
3
Decompression Lever
When depressed, releases compression in the diesel engine combustion
"A"
chamber to allow for manually pull starting the engine. Lever automatically
returns to its up ("off") position when recoil starter is pulled.
4
RUN
Pushed - Enables fuel flow to diesel engine fuel injection pump for starting
Lever (Black)