ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
12
13
14
OPERATING
MAKE SURE
1.
SET IS GROUNDED
2.
TO CHECK OIL
3.
TO CHECK FUEL LEVEL
75
50
100
4.
LOAD CONTACTOR IS OFF
100
25
50
5.
LOAD IS CONNECTED
%
AC
6.
ENGINE AIR INTAKE IS IN
NORMAL POSITION
LOAD
125
VOLTS
0
0
150
MANUAL START
AT 23F OR WARMER
1.
MOVE LEVER TO RUN
2.
PRESS LEVER A
3.
PULL RECOIL STARTER
4.
TURN LOAD CONTACTOR ON
60
58
62
ELECTRIC START
56
64
AT ALL TEMPERATURES
1
HERTZ
65
55
1. MOVE LEVER TO RUN
HOURS 10
2. ATTACH SLAVE POWER
SOURCE
3. PRESS LEVER A: THEN
a. ABOVE 23F
(1) TURN START SWITCH
VOLTAGE ADJ
1A, INST.
SPARE
TO START
-
+
b. AT 23F TO -5F
FUSE
FUSE
(1) PREHEAT FOR 1.5 MINUTES
(2) TURN START SWITCH
TO START
c. AT -5F TO -40F
15
(1) ADD 2 mL OIL TO B
(2) MOVE AIR INTAKE TO COLD
POSITION
18
(3) PREHEAT FOR 3 MINUTES
(4) TURN START SWITCH TO
START PREHEAT
4. TURN LOAD CONTACTOR ON
TO STOP
1. TURN LOAD CONTACTOR OFF
2. PRESS STOP LEVER
17
16
DETAIL A
MEP-531A
Figure 2-1. Operator's Controls and Indicators (Sheet 2 of 4)
2-3