ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-144
(4)
Remove muffler clamp (1, Figure 4-19) from exhaust pipe (8).
(5)
Remove bands (2) from muffler assembly (3) and supports (7).
(6)
Separate exhaust pipe (8) from muffler assembly (3), and remove muffler assembly from generator
set.
(7)
Remove boltss (4), lockwashers (5), washers (6), and supports (7) from top section floor panel.
(8)
Loosen V-band clamp (9) at turbocharger outlet.
(9)
Remove exhaust pipe (8) and V-band clamp (9) from turbocharger outlet.
(10) Inspect muffler assembly (3, Figure 4-19) and exhaust pipe (8) for cracks, excessive corrosion,
clogging, and other damage.
(11) Position V-band clamp (9) and exhaust pipe (8) on turbocharger outlet. Tighten clamp.
(12) Install supports (7), washers (6), lockwashers (5), and boltss (4) on top section floor panel.
(13) Install muffler (3) and bands (2) on supports (7).
(14) Position exhaust pipe (8) on muffler (3), and install muffler clamp (1).
(15) Install roof stiffener assembly and top housing panel. Refer to paragraph 4.7.3.
(16) Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.9.2
Air Cleaner Assembly.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box assembly, paragraph 4.8.1.
(4)
Inspect air cleaner assembly (1, Figure 4-20) and mounting bracket (2) for cracks, dents, blockage,
debris, and other damage.
(5)
Install DCS control box assembly, paragraph 4.8.1.
(6)
Connect negative cable to battery. Close BATTERY ACCESS door.
b. Service.
(1)
Remove air cleaner filter element, Paragraph 4.9.4.
(2)
Wipe inside of air cleaner housing (3, Figure 4-20) with cleaning cloth (Item 8, Appendix E).
(3)
Install new air cleaner filter element, Paragraph 4.9.4.