ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-148
4.9.5
Air Cleaner Hoses.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open left side engine compartment access doors (Figure 1-3).
(3)
Inspect all hoses and tubing (5, 21, 22, and 23, Figure 4-20) for cracks, tears, and holes.
(4)
Inspect hose clamps (4 and 20) for cracks.
(5)
Replace parts as necessary.
(6)
Close engine compartment access doors.
b. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open left side engine compartment access doors (Figure 1-3).
(3)
Loosen hose clamps (4 and 20, Figure 4-20).
(4)
Remove elbow (5) from air cleaner housing (3) and tube assembly (21).
(5)
Remove tube assembly (21) from breather hose (23) and hump hose (22).
(6)
Remove hump hose (22) from turbocharger.
(7)
Remove breather hose (23) from oil breather outlet on valve cover.
c. Service.
(1)
Remove air cleaner hoses, step b above.
(2)
Clean hoses and tubing with cleaning cloth (Item 8, Appendix E) and with water.
(3)
Install air cleaner hoses, step d below.
d. Installation.
(1)
Position hose clamp (20, Figure 4-20) on breather hose (23), and install breather hose on oil
breather.
(2)
Position hose clamp (4) on hump hose (22), and install hump hose on turbocharger.
(3)
Position hose clamp (4) on hump hose (22), and install hump hose on tube assembly (21).
(4)
Position hose clamp (20) on breather hose (23), and install breather hose on tube assembly (21).
(5)
Position hose clamps (4) on elbow (5), and install elbow on air cleaner housing (3) and tube