(10) Place new battery current transducer on bracket (12). Verify that holes line up with mounting
bracket (12).
(11) Attach battery current transducer (1) to bracket (12) with bolts (9), washer (10) and nuts (11).
(12) Feed wire number 310A16 through the battery current transducer.
(13) Strip 1/4 " of insulation from the end of wire 310A16.
(14) Crimp ring terminal (8) to the end of wire 310A16.
(15) Attach wire number 310A16 to the positive post of the alternator with isolating washer (7), terminal
washer (6), washer (5) and nut (4).
(16) Feed wire number 145C16 through the top of the battery current transducer (1) and route to the
battery compartment.
(17) Strip 1/4 " of insulation from the end of wire 145C16.
(18) Crimp ring terminal to the end of wire 145C6.
(19) Attach wire number 145C16 to the positive post of battery number one. Refer to Schematic FO-1.
(20) Reconnect negative cable to battery.
(21) Close battery access door, (Figure 1-2).
(22) Close right side engine compartment access door, (Figure 1-2).
4.14
MAINTENANCE OF LUBRICATION SYSTEM.
__________
WARNING
When disconnecting or removing batteries, disconnect the negative lead that
connects directly to the grounding stud first. Disconnect the negative end of
the interconnection cable next. When installing batteries, reverse the
connection sequence. Failure to comply can cause serious personal injury.
4.14.1 Oil Drain Valve.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS and right side engine compartment access doors (Figure 1-2).
(3)
Inspect oil drain line for cracks, holes, loose or missing hardware, or other damage.
(4)
Close BATTERY ACCESS and right side engine compartment access doors.