ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-176
(10) Ensure fuel drain valve (30) is closed, and service fuel tank. Refer to Table 4-2 for proper fuel.
(11) Check fuel drain valve (30) and fitting for leakage.
(12) Install cap (28) on adapter (29).
(13) Close engine compartment access doors.
(14) Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.11.5 Fuel Level Sender MT5.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open right side engine compartment access doors (Figure 1-2).
(3)
Inspect fuel level sender (39, Figure 4-26) for loose connections and mounting, and other damage.
(4)
Close engine compartment access doors.
b. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), disconnect negative battery cable from battery.
(3)
Open right side engine compartment access doors (Figure 1-3).
(4)
Remove nut (33, Figure 4-26) and electrical lead (34) from fuel level sender (39). Tag lead.
NOTE
Mark position of float when removing sender. Float must be in same position when
installed to ensure clearance with fuel tank.
(5)
Remove screws (35), lockwashers (36), washers (37), electrical lead (38), fuel level sender (39), and
gasket (40) from generator set fuel tank. Tag lead.
(6)
Cover opening in fuel tank.
c. Testing.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove fuel level sender, step b above.
(3)
Position fuel level sender in vertical position, similar to position as installed in fuel tank.
(4)
Set multimeter for ohms. Connect positive lead to fuel level sender terminal and negative lead to
fuel level sender ground.