ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-77
4.7.6
Housing Data Plates.
a. Inspection. Inspect data plates for readability and loose or missing rivets. Refer to paragraph 2.16 for
locations of data plates on housing.
b. Replacement.
(1)
Drill out rivets, and remove data plate from housing. Refer to paragraph 2.16.
(2)
Install data plate on housing with rivets.
4.8
MAINTENANCE OF DCS CONTROL BOX ASSEMBLY
__________
WARNING
When disconnecting or removing batteries, disconnect the negative lead that
connects directly to the grounding stud first. Disconnect the negative end of
the interconnection cable next. When installing batteries, reverse the
connection sequence. Failure to comply can cause serious personal injury.
__________
WARNING
Electronic components of the DCS and CIM are static sensitive. Ensure that
no static discharge occurs when you come in contact with those components.
Failure to comply can cause damage to electronic components.
4.8.1
DCS Control Box
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Inspect DCS control box for cracks, breaks, corrosion, loose paint, and missing parts.
b. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable .
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Remove bolts (1, Figure 4-10), lockwashers (2), and washers (3) securing DCS control box
assembly (12) to top of output box assembly (Figure 5-3).
(5)
Open output box access door (Figure 1-2).
(6)
Remove locknuts (4, Figure 4-10) and bolts (5) securing DCS control box assembly (12) to
generator set.