ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-82
4.8.3
NETWORK FAILURE Light DS5.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Release DCS control panel by turning two fasteners, and lower panel slowly.
(3)
Inspect light housing (11, Figure 4-11) for cracks, corrosion, evidence of shorting, and other
damage.
(4)
Raise and secure DCS control panel.
b. Repair.
(1)
Unscrew to remove press-to-test light (8, Figure 4-11) from light housing (11).
(2)
Screw press-to-test light (8) into light housing (11) to install.
c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable .
(3)
Release DCS control panel by turning two fasteners, and lower panel slowly.
(4)
Tag and disconnect light housing (11, Figure 4-11) electrical leads.
(5)
Remove press-to-test light (8), jamnut (9), washer (10), and light housing (11) from DCS control
panel (6).
(6)
Install light housing (11), washer (10), jamnut (9), and press-to-test light (8) on DCS control panel
(6).
(7)
Tighten jamnuts (9 and 12) to secure light housing (11) to DCS control panel (6).
(8)
Connect light housing (11) electrical leads. Remove tags.
(9)
Raise and secure DCS control panel.
(10) Connect negative battery cable to battery, and close BATTERY ACCESS doors.
4.8.4
Time Meter (TOTAL HOURS) M3.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Release DCS control panel by turning two fasteners, and lower DCS control panel slowly.
(3)
Inspect time meter (3, Figure 4-12) for broken lens, cracked housing, and other damage.